0.3.0 14 November 2026
All changes since version 0.2.0.
HIGHLIGHTS
- Effects on the input: put up to 3 insert effects on what you record, for example a compressor on a synth. What you hear is what you record.
- 16 USB Outputs: send each track or submix to its own channel in your DAW (USB 3-18), and record all tracks at once.
- Load Kit loads the samples of a drum program (.xpm) from the MPC software or an MPC Live, One or X.
- Looper: while you record, you hear the passes that you already recorded.
- Two more insert effects: AIR Lo-Fi and AIR Pitch Shifter.
- Key detection: the Tuner finds the key of a sample, and a new sample gets its key at once (Auto Key).
- Screen Mirror: see the MPC screen live in a browser on your computer, over the USB cable.
- Erase automation in the mixers: hold ERASE and move the control.
- Pad View and Track View: the FADER zooms from 1 to 16 rows.
- COPY can swap two pads, also between two tracks.
- Projects go to the SD card by default, and you can load one project after the other without "Insufficient space on drive".
- Export Stems: each stem has only its own track.
- Knob FX Bypass on B3: B3 turns the Knob FX on or off while the KNOB FX bar shows. This changes B3 (see CHANGED FUNCTIONS); Settings can turn it off.
NEW FUNCTIONS
- Key detection in the Tuner: B2 Key shows the key of the sample on the selected pad, for example "A min". B3 Apply saves it as the key of the sample. The key goes into the project and the WAV file.
- Auto Key: a new sample from Sample Select, Sample Record or Resample gets its key at once. On or off in Settings.
- Sample key by hand: SAMPLE, Tune page, SHIFT + K2 (Key).
- Tuner K2 / K3: set the tune (Semi / Fine) of the selected pad while you read its note.
- Delete Folder: delete a folder on the SD card, with all files in it, from the MPC. SAMPLE SELECT, External, select a folder, SHIFT + B3. The MPC asks first. A folder with the loaded project cannot be deleted.
- Screen Mirror: see the MPC screen live in a browser on your computer, for tutorials and videos. Connect the USB cable and open http://mpc-sample.local:7410. Nothing to set up.
- Effects on the input: put up to 3 insert effects on what you record, for example a compressor or a filter on a synth at the rear input. What you hear on the input is what you record. SAMPLE RECORD, SHIFT + B2 opens the new Input FX page. Before, only the Knob FX could go on the input.
- Sleep (Settings): after 5 to 30 minutes with no input, the screen and all pad and button lights go off, to save the battery. Any button, pad or knob wakes the MPC, and that first touch does nothing else. The MPC does not sleep while it plays or records.
- Input strip in the Ch. Mixer: the far left strip sets the input volume (K1 or the FADER) and shows the input level. The volume is in the monitor and in the recording. SHIFT + B1 (Inserts) opens the Input FX page, and B1 (Back) brings you back to the Ch. Mixer.
- Mixer: hold ERASE and move a control to erase its recorded automation in this sequence: volume, pan or mute in the Ch. Mixer and Pad Mixer, effect on/off and effect knobs on the insert and effect pages. All erases all automation of that track, submix or pad.
- Load Kit loads the samples of a drum program (.xpm) from the MPC software or an MPC Live, One or X into the current track. Only the samples: not the insert effects, not the effect settings and not the pad settings.
- Two more insert effects. AIR Lo-Fi (group Harmonic) makes a sound lo-fi: bit depth, sample rate and clip. AIR Pitch Shifter (group Modulation) changes the pitch of a pad, track, submix or the master and keeps the length (Tune changes both).
- 16 USB Outputs (Settings): the MPC sends tracks and submixes to a computer on 16 more USB audio channels (USB 3-18), as separate outputs in your DAW. Select USB 3 to USB 18 (mono) or a pair with K3 (Out) in the Mixer. A + after the output (USB 5+) shows that another track or submix also plays on it. The setting applies after a restart.
- Step Edit: SHIFT + PLAY with no selection and no loop can start at the cursor, not at the playhead (Settings "Shift+Play Starts").
- Settings: Tap Tempo Light. Blink makes the TAP TEMPO light flash with the tempo, as stock. Dimmed (default) keeps it on, a little dimmed.
- Settings: Pad View Order and Track View Order put pad 1 or track 1 at the top (default) or at the bottom, as on the pads.
CHANGED FUNCTIONS
- B3 works differently while the KNOB FX bar shows: B3 now turns the Knob FX on or off (Bypass), on every screen (also PAD FX and the Tuner). Orange frame = on, orange box = off. Before, B3 did the function of the screen under the bar (for example Looper on SAMPLE RECORD). SHIFT + B3 still does that function. This is on by default. To get the old B3 back: Settings > Knob FX B3 Bypass > Off.
- STOP two times ends the SHIFT + PLAY loop, as PLAY does.
- Pad effects record automation: with SEQ RECORD + PLAY, the knobs on the effect page of a pad effect record their moves, as on a track or a submix. ERASE + knob on that page erases them. Before, a pad effect recorded nothing.
- Root note for KEYS moved to the Tune page of SAMPLE: SHIFT + K1 (Root), next to the new Key (SHIFT + K2). SHIFT + K1 on the Play page is stock Mono/Poly again.
- Stock key guess off: stock guessed a key for every sample on each load, mostly wrong and also on drum hits. A loaded sample keeps the key of its file. A new sample gets its key from Auto Key; set or detect a key with the Tuner or on the Tune page.
- 16 LEVELS: SAMPLE sets 16 Levels off and gives back the normal pads. Before, SAMPLE did nothing in 16 Levels (stock).
- Pad View: a small + on a note shows two or more notes of that pad in one cell, for example a double note at the loop end after a recording. ERASE at the cursor then clears them one by one, and the note that is most on time stays.
- SHIFT + PAD BANK: the track grid shows after 0.3 seconds, as the sequence grid. A quick tap (one pad bank back) shows no grid.
- Rec Quantize strength: the Rec Quantize popup (SHIFT + PAD 10) sets the strength on K2 (Q Str, 0-100). Below 100, a recorded note moves only part of the way to the grid. The project keeps the value. Time Correct always uses 100.
- 16 Levels Scale: while a Chord plays, the pad stays in Poly, so you hear all tones. Before, a Mono pad played only one tone of the chord.
- Looper: while you record, you hear the passes that you already recorded. Before, you heard only the input and recorded "blind".
- Looper: record again on the same pad, and the new take goes on top of the old loop as a new layer. Before, the new take replaced the old loop. One Undo removes only the last layer. With Looper off, a new take replaces the old loop, as before.
- Looper: the loop starts on the start of the sequence loop, also when you started to record in the middle. Thus a play from the start has the full loop in the first pass.
- Looper: a tap on another pad stops the take, as a tap on its own pad. Before, it chopped the take, and the passes were not merged.
- Projects go to the SD card by default: Settings PROJECT Start Drive is External. A project on the SD card keeps the internal storage free. If you changed Settings before, your Start Drive stays.
- SAMPLE RECORD: SHIFT + B2 now opens the Input FX page. Before, it set Rec Input Effects on or off. The Knob FX no longer plays on the input: you hear and record only the effects that you put on the Input FX page. Rec Input Effects in the stock Input Config menu does nothing. B2 on the page turns all input effects on or off (Input FX On or Off). Off = you hear and record the input dry.
- COPY (SHIFT + ERASE) to one pad that has a sample, on the same track or on another track: you can also swap the two pads (B2 Swap). The notes stay on their pads.
- The erase windows (ERASE + knob, fader or pad) show "No automation to erase." when there is nothing to erase. Stock showed nothing.
- The erase window tells what it erases: ERASE PAD AUTOMATION, ERASE TRACK AUTOMATION or ERASE SUBMIX AUTOMATION.
- The Ch. Mixer sets the MIDI channel of a track too (SHIFT + K3 on a track strip), as the Track page.
- A muted track or pad also sends no MIDI notes. With Mute Type Audio, a MIDI note that sounds stops when you mute.
- A track with its own MIDI channel follows Pad MIDI Out in MIDI Config (Always, When Empty, Never). Before, all its pads always sent MIDI, so the pads with a sample also played the external synth. After the update from 0.2.0, your synth can follow the tempo but play no notes: then Pad MIDI Out is When Empty or Never. Set it to Always (the stock default) and all pads send MIDI again.
- Chop Mode opens at once on a sample without chops, also on a long sample: the Chop Type is Manual, with one slice. Stock starts a Threshold chop there, and that takes long. For an auto chop, turn K3 to Threshold or Regions.
- Settings: Shift+SEQ is a Shortcuts line. It opens the Track View (default), the Pad View or another screen.
- Settings: Shift+PAD FX has a third choice, Last Used. SHIFT + PAD FX then opens the screen that you used last: Flex Beat or Pad FX.
- Settings: SHIFT + ENCODER goes from group to group, so you find a setting faster in the long list.
- Pad Mixer: a pad strip shows the pad colour that you give it with Rename. A pad without its own colour stays white.
- Pad View and Track View show 1 to 16 rows (Settings: Pad View Rows, Track View Rows). The FADER zooms the view: up = fewer, bigger rows (Fader Overrides: Pad / Track View = Zoom, the default for a new install).
- Fader Overrides: one page sets what the FADER does in Sample Select and Load Project (Scroll), in Pad View and Track View (Nudge or Zoom) and in Pad FX with Fixed on (Effect Mix). Fader Menu: the FADER does what you set in the FADER menu. Open it with B2 in the FADER menu, or in Settings (SYSTEM). It replaces the setting Fader Scrolls List. Your saved choices stay.
- Automate: a filter fade on many tracks can use one filter on a submix in place of one filter per track. The filter comes only at Do It!.
- The USB audio output to a computer is about 5 ms later than before (all USB channels). This prevents short gaps of silence. Your DAW does not know this delay: if a recording from the MPC is late, set a recording offset in the DAW.
FIXED
- Tuner on SAMPLE RECORD: a pad selects the pad for Apply. Before, a pad started a recording under the Tuner.
- Explode, Dup. Track (To Submix) and Chop Mode Extract (To Track): when the effects cannot be copied, nothing changes and a popup tells you ("FX Cannot Be Copied"). Before, the new tracks were made with only a part of the effects. If a copy still fails, the popup says "Press Undo".
- Effect page: each ENCODER step changes the value, in the two directions. Before, some knobs did not move with the ENCODER, or only to the left (for example Output and Ratio on the Bus Compressor).
- To Seq and Looper: a take plays exactly on the beat where you played it. Before, it played about 9 ms late (the record delay of the input).
- Save Project: when you save a loaded project with the same name, the MPC saves over that project. Before, it could save a new copy in another folder. The next load then opened the old project, without your changes.
- Home Folder: Sample Select stays in the folder where you load a sample. Before, each load with the ENCODER went back to the Home Folder.
- Internal storage: the project safety net gives back the space of old samples. Before, old QOL-Recovery projects and a New Project kept them on the internal storage, and the MPC showed "Insufficient space on drive" often. Now only the newest QOL-Recovery project stays, unless you saved over it.
- Load Project: you can load one project after the other. Before, the project safety net kept the samples of the previous project on the internal storage, so the next load showed "Insufficient space on drive" and the open project was then empty.
- Resample one pad (B2 Pad): the new pad keeps the KEYS root note of the pad that you resample. Before, it went back to the default root, so a MIDI keyboard or Scale played the new pad at another pitch, for example much higher.
- Resample one pad: Redo keeps the settings of the new pad (KEYS root note, route, Mute Group, Mono/Poly, volume). Before, Redo set them back to the default values.
- New Track: a new track starts with the default settings, as a new drum track on an MPC: no insert effects, pan in the centre, default volume, output to the Master. Before, it took the settings of the last track, so for example a last track panned to the left made every new track play only on the left.
- Export Stems: each stem has only its own track, also when the sequence has recorded track mutes (for example after Song > Export > Sequence). Before, the recorded unmutes of the other tracks played in each stem, so every stem was the full mix.
- ERASE + pad in Track Mute, and ERASE + FADER on Track Volume: All erases all automation of that track in the sequence: track mutes, Track Volume and the automation of all its pads. Before, All did not erase the track mutes, and with the FADER it erased the automation of a pad.
- ERASE + knob, All: also erases the automation of the Insert FX of the pad. Before, that automation stayed.
- Delete an insert effect in the Mixer: one UNDO puts back the effect and its automation. The on/off automation of the slot goes too, so a new effect in the slot does not switch on and off by itself. Before, UNDO took two steps.
- COPY (SHIFT + ERASE): a pad that you push while you still hold SHIFT is a COPY destination. Before, SHIFT + PAD 7 opened the Tuner and the copy did not happen. This was also so for each pad with a Shortcuts function.
- A track that goes (Delete in Track View, or Undo / Redo of New Track, Dup. Track or Explode): its MIDI notes that sound stop. Before, a note stayed on at the external synth.
- MIDI out: a 16 LEVELS Scale pad with a Chord on a track with MIDI Glob. sends one note per press, as stock 16 Levels. Before, it sent one note for each chord tone and only one note-off, so notes hung on the synth.
- MIDI out: on a track with its own MIDI channel, 16 LEVELS Scale or Tune with NOTE REPEAT (also with the Arp) ends each note. Before, when you released the pad before NOTE REPEAT, the last note stayed on at the synth, also after STOP.
- Sample Record To Seq with a loop (SHIFT + PLAY): the recording and the note stay in the loop, at the time that the recording starts. Before, the note went to bar 1, outside the loop.
- SHIFT + PLAY starts the loop safely. Before, the MPC sometimes crashed after SHIFT + PLAY.
- Chop Mode: when you close it, the SAMPLE screen shows the pad bank of before Chop Mode again. Before, it stayed on the last slice bank, far from the bank of your sample.
- Track View: SHIFT + ENCODER moves the cursor track smoothly, also when you turn fast. Before, the cursor sometimes jumped back one track for a moment.
- Track View: the pad that you hit turns yellow, as on the SAMPLE screen. Before, only some pads turned yellow.
- Load Kit on a .mpcsample kit loads the kit into the current track. The other tracks and the notes stay, and one UNDO removes the kit. Before, it removed all other tracks and the notes.
- Automate: your own volume or filter value in a sequence without the fade stays after the next start, also when you made the sequence with the fade longer. Before, it could go back to the old value when the project saved with the faded sequence selected.
- Sequence change while the MPC plays, with many tracks: no more short gaps on the USB audio output. Before, a late change made a gap of silence on the computer.
FIXED (STOCK PROBLEMS)
- MIDI Program Change follows MIDI In Channel in MIDI Config. With a channel set, a Program Change on another channel does not change the sequence. Stock changed the sequence on all channels.
KNOWN ISSUES
- A pad with Out set to a submix or an output still stops at once (with a click) when its track gets an Audio Mute.
- 16 USB Outputs On: the MPC needs a few seconds more to start.
- A project with a track or submix on a USB output: with 16 USB Outputs Off, or on a stock MPC Sample, the load shows "Unsupported Outputs". RESOLVE sets these outputs to the Master.
- Without SampQOL OS, a track with its own MIDI channel sends the 16 Levels source note, not the real note. A track with MIDI Off sends as MIDI Config sets.
- Without SampQOL OS, a pad mute always sounds as Mute Type Audio.
- Without SampQOL OS, a pad with Stereo plays both channels.
- Without SampQOL OS, the track mutes of each sequence do not play (also after Song Export). All tracks sound.
- "Insufficient space on drive" is about the internal storage, not the SD card. See Troubleshooting in the MANUAL.